Get In Touch

Single product

PV3500 PRO Series (4-12KW)

Low Frequency Off Grid Solar Inverter

PV3500 PRO series is a multi-function inverter ,combining functions of inverter and MPPT solar charger controller, solar charger and battery charger to offer uninterruptible power support. The comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and selectable input voltage based on different applications.

Features:

• Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
• Built-in MPPT solar charge controller 80A/100A/200A
• MPPT efficiency max 98%
• Powerful charge rate up to 140Amp
• DC start &Automatic Self-Diagnostic Function
• WIFI / USB monitoring function (wi-fi optional)
• Supporting AGS, BTS port
• Compatible to generator

Specification:

MODEL PV35 PRO-4K PV35 PRO-5K PV35 PRO-6K
Nominal Battery System Voltage 24V 48V 24V 48V 48V
INVERTER OUTPUT
Rated power 4KW 5KW 6KW
Surge rating 12000VA 15000VA 18000VA
Capable of starting electric motor 2HP 2HP 3HP
Waveform Pure sine wave / same as input (bypass mode)
Nominal output voltage RMS 220V / 230V / 240VAC (±10%RMS)
Output frequency 50Hz / 60Hz ± 0.3Hz
Inverter effciency(peak) >85%
Line mode efficiency >95%
Power factor 1.0
Typical transfer time 20ms(max)
AC INPUT
Voltage 230VAC
Selectable voltage range 90-280 VAC (APL)
Frequency range 50Hz / 60Hz
BATTERY
Low battery voltage cutoff 20-24VDC for 24VDC mode (40-48VDC for 48VDC mode)
Low battery voltage recover 21-25VDC for 24VDC mode (42-50VDC for 48VDC mode)
High battery voltage cutoff 30VDC for 24VDC mode (60VDC for 48VDC mode)
High battery voltage recover 28.5VDC for 24VDC mode (57VDC for 48VDC mode)
Idle consumption-search mode <30W when power saver on
AC CHARGER
Output voltage Depends on battery type
Charger AC input breaker rating 40A 40A 50A
Overcharge protection S.D. 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode )
Maximum charge current 80A 60A 100A 70A 80A
BTS
Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
Input voltage waveform Sine wave (grid or generator)
Nominal input frequency 50Hz or 60Hz
Overload protection (SMPS Load) Circuit breaker
Output short circuit protection Circuit breaker
Bypass breaker rating 40A
Max bypass current 40Amp
SOLAR CHARGER
Maximum PV charge current 80A
DC voltage 24V / 48V Auto work
Maximim PV array power 2000W 4000W 2000W 4000W 4000W
MPPT range @ operating voltage(VDC) 32-145VDC for 24V mode,64-145V for 48V mode
Maximum PV array open circuit voltage 145VDC
Maximum effciency >98%
Standby power consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall mount
Dimensions (W*H*D) 620*385*215mm
Net weight (solar CHG) (kg) 36 41 41
Shipping dimensions (W*H*D) 755*515*455mm
Shipping weight (Solar CHG) (kg) 56 61 64
OTHER
Operation temperature range 0°C to 40°C
Storage temperature -15°C to 60°C
Audible noise 60dB MAX
Display LED+LCD
MODEL PV35 PRO-8K PV35 PRO-10K PV35 PRO-12K
Nominal Battery System Voltage 48VDC 48VDC 48VDC
INVERTER OUTPUT
Rated power 8.0KW 10.0KW 12.0KW
Surge rating 24000VA 30000VA 36000VA
Capable of starting electric motor 4HP 5HP 6HP
Waveform Pure sine wave / same as input (bypass mode)
Nominal output voltage RMS 220V / 230V / 240VAC (±10%RMS)
Output frequency 50Hz / 60Hz ± 0.3Hz
Inverter effciency(peak) >88%
Line mode efficiency >95%
Power factor 1.0
Typical transfer time 20ms(max)
AC INPUT
Voltage 230VAC
Selectable voltage range 90-280 VAC (APL)
Frequency range 50Hz / 60Hz
BATTERY
Low battery voltage cutoff 20-24VDC for 24VDC mode (40-48VDC for 48VDC mode)
Low battery voltage recover 21-25VDC for 24VDC mode (42-50VDC for 48VDC mode)
High battery voltage cutoff 30VDC for 24VDC mode (60VDC for 48VDC mode)
High battery voltage recover 28.5VDC for 24VDC mode (57VDC for 48VDC mode)
Idle consumption-search mode <80W when power saver on
AC CHARGER
Output voltage Depends on battery type
Charger AC input breaker rating 80A 80A 80A
Overcharge protection S.D. 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode )
Maximum charge current 100A 120A 140A
BTS
Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS & PROTECTION
Input voltage waveform Sine wave (grid or generator)
Nominal input frequency 50Hz or 60Hz
Overload protection (SMPS Load) Circuit breaker
Output short circuit protection Circuit breaker
Bypass breaker rating 63A 63A 63A
Max bypass current 80Amp
SOLAR CHARGER
Maximum PV charge current 100A(200A optional)
DC voltage 48V
Maximim PV array power 5000W(10000W for 200A optional)
MPPT range @ operating voltage(VDC) 64~145VDC
Maximum PV array open circuit voltage 145VDC
Maximum effciency >98%
Standby power consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall mount
Dimensions (W*H*D) 670*410*215mm
Net weight (solar CHG) (kg) 69+2.5 75.75+2.5 75.75+2.5
Shipping dimensions (W*H*D) 884*618*443mm
Shipping weight (Solar CHG) (kg) 82.5+2.5 89+2.5 92+2.5
OTHER
Operation temperature range 0°C to 40°C
Storage temperature -15°C to 60°C
Audible noise 60dB MAX
Display LED+LCD