Features:
• Smart LCD setting(Working modes, Charge Current, Charge voltage, etc.)
• Built-in MPPT solar charge controller 80A/100A/200A
• MPPT efficiency max 98%
• Powerful charge rate up to 140Amp
• DC start &Automatic Self-Diagnostic Function
• WIFI / USB monitoring function (wi-fi optional)
• Supporting AGS, BTS port
• Compatible to generator
Specification:
MODEL | PV35 PRO-4K | PV35 PRO-5K | PV35 PRO-6K | ||
---|---|---|---|---|---|
Nominal Battery System Voltage | 24V | 48V | 24V | 48V | 48V |
INVERTER OUTPUT | |||||
Rated power | 4KW | 5KW | 6KW | ||
Surge rating | 12000VA | 15000VA | 18000VA | ||
Capable of starting electric motor | 2HP | 2HP | 3HP | ||
Waveform | Pure sine wave / same as input (bypass mode) | ||||
Nominal output voltage RMS | 220V / 230V / 240VAC (±10%RMS) | ||||
Output frequency | 50Hz / 60Hz ± 0.3Hz | ||||
Inverter effciency(peak) | >85% | ||||
Line mode efficiency | >95% | ||||
Power factor | 1.0 | ||||
Typical transfer time | 20ms(max) | ||||
AC INPUT | |||||
Voltage | 230VAC | ||||
Selectable voltage range | 90-280 VAC (APL) | ||||
Frequency range | 50Hz / 60Hz | ||||
BATTERY | |||||
Low battery voltage cutoff | 20-24VDC for 24VDC mode (40-48VDC for 48VDC mode) | ||||
Low battery voltage recover | 21-25VDC for 24VDC mode (42-50VDC for 48VDC mode) | ||||
High battery voltage cutoff | 30VDC for 24VDC mode (60VDC for 48VDC mode) | ||||
High battery voltage recover | 28.5VDC for 24VDC mode (57VDC for 48VDC mode) | ||||
Idle consumption-search mode | <30W when power saver on | ||||
AC CHARGER | |||||
Output voltage | Depends on battery type | ||||
Charger AC input breaker rating | 40A | 40A | 50A | ||
Overcharge protection S.D. | 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode ) | ||||
Maximum charge current | 80A | 60A | 100A | 70A | 80A |
BTS | |||||
Continuous output power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature | ||||
BYPASS & PROTECTION | |||||
Input voltage waveform | Sine wave (grid or generator) | ||||
Nominal input frequency | 50Hz or 60Hz | ||||
Overload protection (SMPS Load) | Circuit breaker | ||||
Output short circuit protection | Circuit breaker | ||||
Bypass breaker rating | 40A | ||||
Max bypass current | 40Amp | ||||
SOLAR CHARGER | |||||
Maximum PV charge current | 80A | ||||
DC voltage | 24V / 48V Auto work | ||||
Maximim PV array power | 2000W | 4000W | 2000W | 4000W | 4000W |
MPPT range @ operating voltage(VDC) | 32-145VDC for 24V mode,64-145V for 48V mode | ||||
Maximum PV array open circuit voltage | 145VDC | ||||
Maximum effciency | >98% | ||||
Standby power consumption | <2W | ||||
MECHANICAL SPECIFICATIONS | |||||
Mounting | Wall mount | ||||
Dimensions (W*H*D) | 620*385*215mm | ||||
Net weight (solar CHG) (kg) | 36 | 41 | 41 | ||
Shipping dimensions (W*H*D) | 755*515*455mm | ||||
Shipping weight (Solar CHG) (kg) | 56 | 61 | 64 | ||
OTHER | |||||
Operation temperature range | 0°C to 40°C | ||||
Storage temperature | -15°C to 60°C | ||||
Audible noise | 60dB MAX | ||||
Display | LED+LCD |
MODEL | PV35 PRO-8K | PV35 PRO-10K | PV35 PRO-12K |
---|---|---|---|
Nominal Battery System Voltage | 48VDC | 48VDC | 48VDC |
INVERTER OUTPUT | |||
Rated power | 8.0KW | 10.0KW | 12.0KW |
Surge rating | 24000VA | 30000VA | 36000VA |
Capable of starting electric motor | 4HP | 5HP | 6HP |
Waveform | Pure sine wave / same as input (bypass mode) | ||
Nominal output voltage RMS | 220V / 230V / 240VAC (±10%RMS) | ||
Output frequency | 50Hz / 60Hz ± 0.3Hz | ||
Inverter effciency(peak) | >88% | ||
Line mode efficiency | >95% | ||
Power factor | 1.0 | ||
Typical transfer time | 20ms(max) | ||
AC INPUT | |||
Voltage | 230VAC | ||
Selectable voltage range | 90-280 VAC (APL) | ||
Frequency range | 50Hz / 60Hz | ||
BATTERY | |||
Low battery voltage cutoff | 20-24VDC for 24VDC mode (40-48VDC for 48VDC mode) | ||
Low battery voltage recover | 21-25VDC for 24VDC mode (42-50VDC for 48VDC mode) | ||
High battery voltage cutoff | 30VDC for 24VDC mode (60VDC for 48VDC mode) | ||
High battery voltage recover | 28.5VDC for 24VDC mode (57VDC for 48VDC mode) | ||
Idle consumption-search mode | <80W when power saver on | ||
AC CHARGER | |||
Output voltage | Depends on battery type | ||
Charger AC input breaker rating | 80A | 80A | 80A |
Overcharge protection S.D. | 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode ) | ||
Maximum charge current | 100A | 120A | 140A |
BTS | |||
Continuous output power | Yes Variances in charging voltage & S.D. voltage base on the battery temperature | ||
BYPASS & PROTECTION | |||
Input voltage waveform | Sine wave (grid or generator) | ||
Nominal input frequency | 50Hz or 60Hz | ||
Overload protection (SMPS Load) | Circuit breaker | ||
Output short circuit protection | Circuit breaker | ||
Bypass breaker rating | 63A | 63A | 63A |
Max bypass current | 80Amp | ||
SOLAR CHARGER | |||
Maximum PV charge current | 100A(200A optional) | ||
DC voltage | 48V | ||
Maximim PV array power | 5000W(10000W for 200A optional) | ||
MPPT range @ operating voltage(VDC) | 64~145VDC | ||
Maximum PV array open circuit voltage | 145VDC | ||
Maximum effciency | >98% | ||
Standby power consumption | <2W | ||
MECHANICAL SPECIFICATIONS | |||
Mounting | Wall mount | ||
Dimensions (W*H*D) | 670*410*215mm | ||
Net weight (solar CHG) (kg) | 69+2.5 | 75.75+2.5 | 75.75+2.5 |
Shipping dimensions (W*H*D) | 884*618*443mm | ||
Shipping weight (Solar CHG) (kg) | 82.5+2.5 | 89+2.5 | 92+2.5 |
OTHER | |||
Operation temperature range | 0°C to 40°C | ||
Storage temperature | -15°C to 60°C | ||
Audible noise | 60dB MAX | ||
Display | LED+LCD |