Get In Touch

Single product

PV3000 VPM Series (1-3KVA)

Low Frequency Off Grid Solar Inverter

PV3000 VPM series is very economical pure sine wave solar inverter, inbuilt with 60A MPPT Charger and AC Charger from 20A to 60A; Solar/AC priority is configurable, when setting solar priority, solar will charge batteries as first priority, and AC can also charge batteries when solar charger current is too lower, in this way system charge is optimazed best. It enables inverter to operate with all kinds of home appliances.

Features:

• Pure sine wave output
• 3 Steps charging
• Overload and short-circuit protection
• Set charging voltage/charging current
• Battery low voltage shutdown point can be set to 10 / 10.5 / 11 / 11.5V
• Power-save mode
• Set utility priority/battery priority
• Set utility input wide/narrow range
• Inverter voltage can be set to 110V/115V/120V or 220V/230V/240V
• Inverter frequency can be set to 50Hz/60Hz
• Set utility charging on/off switch
• Inbuilt with 60A MPPT Solar Charge Controller
• Acid or Lithium Select
• WiFi port (optional)

Specification:

MODEL PV30-1K VPM PV30-1.5K VPM PV30-2K VPM PV30-3K VPM
Nominal Battery System Voltage 12VDC 24VDC 12VDC 24VDC 12VDC 24VDC 24VDC
INVERTER OUTPUT
Rated Power 1000VA 1500VA 2000VA 3000VA
Surge Rating 3000VA 4500VA 6000VA 9000VA
Capable Of Starting Electric Motor 1HP 1HP 1HP 2HP
Waveform Pure sine wave / same as input (bypass mode)
Nominal Output Voltage RMS 110V /115V / 120V / 220V / 230V / 240VAC (±10% RMS)
Output Frequency 50Hz / 60Hz ±0.3Hz
Inverter Efficiency (Peak) >88%
Line Mode Efficiency >95%
Power Factor 0.7
Typical Transfer Time 10ms(max)
AC INPUT
Voltage 230VAC
Selectable Voltage Range 96~132VAC 155~280VAC(For personal computers)
Frequency Range 50Hz / 60Hz(Auto sensing) 40~80Hz
BATTERY
Minimum Start Voltage (10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Alarm (10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
Low Battery Cut Off 10V / 10.5V / 11V / 11.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC)
High Voltage Alarm (13.8-14.5V)+1V for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
High Battery Voltage Recover (13.8-14.5V)+0.5V  for 12VDC mode  (*2 for 24VDC, *4 for 48VDC)
Idie Consumption-Search Mode Load ≤50±20W(120V)/100±20W(220V)
CHARGER
Output Voltage Depends on battery type
Charge AC Input Breaker Rating 120V 1K/12A 1.5K/16A 2K/30A 3K/40A
230V 1-1.5K/10A 2-3K/30A
Overcharge Protection S.D. 15.7VDC for 12VDC mode (*2 for 24VDC mode)
Maximum Charge Current 30A 20A 45A 25A 60A 30A 40A
BYPASS & PROTECTION
Input Voltage Waveform Sine wave (grid or generator)
Nominal Input Frequency 50Hz or 60Hz
Overload Protection (SMPS Load) Circuit breaker
Output Short Circuit Protection Circuit breaker
AC Input Breaker 1-3K/30A
SOLAR CHARGER
Maximum PV Array Power 1000W 2000W 1000W 2000W 1000W 2000W 2000W
Maximum PV Charge Current 60A
DC Voltage 12V / 24V auto work
MPPT Range @ Operating Voltage 12V: 16~75VDC; 24V: 32-100VDC
Maximum PV Array Open Circuit Voltage 12V:75VDC; 24V:100VDC
Standby Power Consumption <2W
MECHANICAL SPECIFICATIONS
Mounting Wall Mount
Dimensions (W*H*D) 302.8*460*199.8mm
Net Weight (Solar CHG)(kg) 16.5 17 21.1 20 24.5
Shipping Dimensions (W*H*D) 400*319*615mm
Shipping Weight (Solar CHG)(kg) 19.3 20 24.1 22.8 29.1
OTHER
Operation Temperature Range 0℃ to 40℃
Storage Temperature -15℃ to 60℃
Audible Noise 60dB MAX
Display LED+LCD