Features:
• Pure sine wave output
• 3 Steps charging
• Overload and short-circuit protection
• Set charging voltage/charging current
• Battery low voltage shutdown point can be set to 10 / 10.5 / 11 / 11.5V
• Power-save mode
• Set utility priority/battery priority
• Set utility input wide/narrow range
• Inverter voltage can be set to 110V/115V/120V or 220V/230V/240V
• Inverter frequency can be set to 50Hz/60Hz
• Set utility charging on/off switch
• Inbuilt with 60A MPPT Solar Charge Controller
• Acid or Lithium Select
• WiFi port (optional)
Specification:
MODEL | PV30-1K VPM | PV30-1.5K VPM | PV30-2K VPM | PV30-3K VPM | ||||
---|---|---|---|---|---|---|---|---|
Nominal Battery System Voltage | 12VDC | 24VDC | 12VDC | 24VDC | 12VDC | 24VDC | 24VDC | |
INVERTER OUTPUT | ||||||||
Rated Power | 1000VA | 1500VA | 2000VA | 3000VA | ||||
Surge Rating | 3000VA | 4500VA | 6000VA | 9000VA | ||||
Capable Of Starting Electric Motor | 1HP | 1HP | 1HP | 2HP | ||||
Waveform | Pure sine wave / same as input (bypass mode) | |||||||
Nominal Output Voltage RMS | 110V /115V / 120V / 220V / 230V / 240VAC (±10% RMS) | |||||||
Output Frequency | 50Hz / 60Hz ±0.3Hz | |||||||
Inverter Efficiency (Peak) | >88% | |||||||
Line Mode Efficiency | >95% | |||||||
Power Factor | 0.7 | |||||||
Typical Transfer Time | 10ms(max) | |||||||
AC INPUT | ||||||||
Voltage | 230VAC | |||||||
Selectable Voltage Range | 96~132VAC 155~280VAC(For personal computers) | |||||||
Frequency Range | 50Hz / 60Hz(Auto sensing) 40~80Hz | |||||||
BATTERY | ||||||||
Minimum Start Voltage | (10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
Low Battery Alarm | (10V / 10.5V / 11V / 11.5V )+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
Low Battery Cut Off | 10V / 10.5V / 11V / 11.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
High Voltage Alarm | (13.8-14.5V)+1V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
High Battery Voltage Recover | (13.8-14.5V)+0.5V for 12VDC mode (*2 for 24VDC, *4 for 48VDC) | |||||||
Idie Consumption-Search Mode | Load ≤50±20W(120V)/100±20W(220V) | |||||||
CHARGER | ||||||||
Output Voltage | Depends on battery type | |||||||
Charge AC Input Breaker Rating | 120V | 1K/12A | 1.5K/16A | 2K/30A | 3K/40A | |||
230V | 1-1.5K/10A | 2-3K/30A | ||||||
Overcharge Protection S.D. | 15.7VDC for 12VDC mode (*2 for 24VDC mode) | |||||||
Maximum Charge Current | 30A | 20A | 45A | 25A | 60A | 30A | 40A | |
BYPASS & PROTECTION | ||||||||
Input Voltage Waveform | Sine wave (grid or generator) | |||||||
Nominal Input Frequency | 50Hz or 60Hz | |||||||
Overload Protection (SMPS Load) | Circuit breaker | |||||||
Output Short Circuit Protection | Circuit breaker | |||||||
AC Input Breaker | 1-3K/30A | |||||||
SOLAR CHARGER | ||||||||
Maximum PV Array Power | 1000W | 2000W | 1000W | 2000W | 1000W | 2000W | 2000W | |
Maximum PV Charge Current | 60A | |||||||
DC Voltage | 12V / 24V auto work | |||||||
MPPT Range @ Operating Voltage | 12V: 16~75VDC; 24V: 32-100VDC | |||||||
Maximum PV Array Open Circuit Voltage | 12V:75VDC; 24V:100VDC | |||||||
Standby Power Consumption | <2W | |||||||
MECHANICAL SPECIFICATIONS | ||||||||
Mounting | Wall Mount | |||||||
Dimensions (W*H*D) | 302.8*460*199.8mm | |||||||
Net Weight (Solar CHG)(kg) | 16.5 | 17 | 21.1 | 20 | 24.5 | |||
Shipping Dimensions (W*H*D) | 400*319*615mm | |||||||
Shipping Weight (Solar CHG)(kg) | 19.3 | 20 | 24.1 | 22.8 | 29.1 | |||
OTHER | ||||||||
Operation Temperature Range | 0℃ to 40℃ | |||||||
Storage Temperature | -15℃ to 60℃ | |||||||
Audible Noise | 60dB MAX | |||||||
Display | LED+LCD |